首頁 Home Product Veterinary Drug Residues Chlortetracycline ELISA Test Kit

Chlortetracycline ELISA Test Kit

Analyte:Antibiotic Residue

Samples:Milk, milk powder, honey

Specification
96 Test/Kit
Product introduction
Summary

Chlortetracycline (CTC) is a high-efficiency broad-spectrum antibiotic that has a strong inhibitory effect on a variety of pathogens and is often used in the treatment of various infectious diseases in animals. However, its residues in animal meat, milk, eggs and other foods pose a serious threat to human health, and can cause diseases such as aplastic anemia and agranulocytosis. Low-concentration drug residues can also induce drug resistance of pathogenic bacteria.

? This kit is a detection product developed by the application of ELISA technology. Compared with instrument analysis technology, it has the advantages of fast, simple, accurate and high sensitivity. The operating time is 45 minutes, which can minimize operating errors and work intensity.



Intended Use

The estriol ELISA Kit is intended for the quantitative analysis of estriol in commodities such as honey and raw milk.


Available Products

P/N? ? ??Sensitivity? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ?Sample? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ??
SC00500.1μg/kg? ? ? ? ? ? ?Honey, milk, feed


Precautions
1. Adhere to the instructions of test procedures. Do not run more than 8 tests at one time. 2. Store test kits at 2-8?C when not in use, and do not use the kits beyond the expiration date. 3. Please don’t touch the membrane on the strips. 4. Remove microwell sealer slightly to prevent the powder from being released from the wells. 5. The sample to be tested must be a homogeneous liquid which cannot be agglomerated, fermented, rancid precipitated, etc., and cannot be colostrum. 6. Avoid direct sunlight and direct blows during testing. 7. Do not re-use pipette tips, test strips or microwells. 8. The unsealed microwells should be used within 1 hour. 9. Do not take tap-water, distilled water or deionized water as the negative control. 10. This test method is just used for rapid screening purpose, if positive results are occurred, please verify them by a quantitative method. 11. Considering that all materials, containers and devices exposed to the sample are contaminated with harmful substance,please wear protective gloves and safety glasses while using the kit. 12. The components in this test kit have been quality control tested as a standard batch unit. Do not mix components from different lot numbers. 13. Any problem encountered during usage, please contact with the supplier.
More Products